Configuring the Camera
BASLER A600
f 4-47
DRAFT
Register Name: Frame Interval Inquiry
Offset from Base Address: 0x050
Field Bit Description
Frame Interval 0 ... 31 Indicates the current frame period in seconds. This value will be up-
dated when you adjust any register that affects the frame period.
The value in this register is a standard IEEE-754 single precision (32
bit) floating point number.
Register Name: Data Depth Inquiry
Offset from Base Address: 0x054
Field Bit Description
Data Depth 0 ... 7 Indicates the effective depth of the data in the transmitted images.
The value in this register depends on the setting in the Format 7, Mode
3 Color Coding ID register (see page 4-43).
This field is read only.
Color Coding ID setting: Effective data depth indicated:
ID = 0 (Mono 8) 8 bits/pixel
---
8 ... 31 Reserved