Basler A600f Bedienungsanleitung Seite 107

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 180
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 106
Configuring the Camera
BASLER A600
f 4-41
DRAFT
Register Name: Value Setting
Offset from Base Address: 0x07C
Field Bit Description
Presence Inq 0 Indicates whether the fields in this register are valid.
0 = not valid 1 = valid
The fields in this register are valid on A601fc and A602fc cameras.
The Presence Inq field is read only.
Setting 1
1 On A600f cameras, this field is not relevant and should be ignored.
(Updates to the register values monitored by this field are performed
automatically.)
---
2 ... 7 Reserved
Error Flag 1 8 Indicates whether the combination of the values in the ISO Speed reg-
ister and in the Format 7 Mode 1 Image Position, Image Size and Color
Coding ID registers is acceptable.
0 = acceptable
1 = not acceptable and no image capture can be started
Error Flag 2
9 Indicates whether the value in the Bytes per Packet register is accept-
able.
0 = acceptable
1 = not acceptable and no image capture can be started
This field is updated whenever a value is written in the Bytes per
Packet register.
---
10 ... 31 Reserved