Physical Interface AW00118501000
36 Basler racer Camera Link
5.6.2.1 Minimum Output Pulse Width
You can use the minimum output pulse width feature to ensure that even very narrow camera output
signals will reliably be detected by other devices. The feature allows you to set the output signal to
a minimum width.
Setting the Minimum Output Pulse Width Using Basler pylon
The MinOutPulseWidthAbs parameter sets the CL Spare output signals to a minimum width. The
parameter is set in microseconds and can be set in a range from 0 to 100 µs
You can set the Line Selector and the value of the MinOutPulseWidthAbs parameter from within
your application software by using the pylon API. The following code snippet illustrates using the
API to set the selector and the parameter value:
// Select the output line
Camera.LineSelector.SetValue(LineSelector_CLSpare);
// Set the parameter value to 10.0 microseconds
Camera.MinOutPulseWidthAbs.SetValue(10.0);
For detailed information about using the pylon API, refer to the Basler pylon Programmer’s Guide
and API Reference.
You can also use the Basler pylon Viewer application to easily set the parameters.
For more information about selecting the source signal for an output line on the camera, see
Section 5.6.2.3 on page 37.
Setting the Minimum Output Pulse Width Using Direct Register Access
To set the value for the minimum output pulse width via direct register access:
Set the value of the Min Out Pulse Width CL Spare register as desired (the value represents
microseconds).
For more information about direct register access, see Section 3.2 on page 16.