Seitenansicht 41
Physical Interface AW00118501000
34 Basler racer Camera Link
Setting an Input Line for Invert Using Direct Register Access
To set the invert function on an input line via direct register access:
For the CC1 line, set the value of the Line Inverter CC1 register to 0 (false) or 1 (true) as
desired.
For the CC2 line, set the value of the Line Inverter CC2 register.
For the CC3 line, set the value of the Line Inverter CC3 register.
For the CC4 line, set the value of the Line Inverter CC4 register.
For more information about direct register access, see Section 3.2 on page 16.
5.6.1.3 Selecting an Input Line as a Source Signal for a Camera
Function
You can select an input line as the source signal for the following camera function:
the Line Start Trigger
Note that to use an input line as the source signal for a camera function, you must apply a signal to
the input line that is appropriately timed for the function.
For detailed information about selecting an input line as the source signal for the camera’s Line Start
Trigger function, see Section 6.1 on page 43.
Default Input Line Selection
Line CC1 is selected as the source signal for the camera’s Line Start Trigger function.