AW00104701000 I/O Control
Basler scout light GigE 73
8.2 Configuring the Output Line
8.2.1 Assigning a Camera Output Signal to the
Physical Output Line
You can use the camera’s output signal assignment capability to assign one of the camera’s
standard output signals as the source signal for the physical output line. The camera has a variety
of standard output signals available including:
Acquisition Trigger Wait (only available when the image acquisition control is set to standard
mode)
Trigger Ready
Exposure Active
Timer 1
You can also designate the output line as "user settable". If the output line is designated as user
settable, you can use the camera’s API to set the state of the line as desired.
To assign an output signal to the output line or to designate the line as user settable:
Use the Line Selector to select Output Line 1.
Set the value of the Line Source Parameter to one of the available output signals or to user
settable. This will set the source signal for the output line
.
You can set the Line Selector and the Line Source parameter value from within your application
software by using the pylon API. The following code snippet illustrates using the API to set the
selector and the parameter value:
Camera.LineSelector.SetValue( LineSelector_Out1 );
Camera.LineSource.SetValue( LineSource_ExposureActive );
For detailed information about using the pylon API, refer to the Basler pylon Programmer’s Guide
and API Reference.
You can also use the Basler pylon Viewer application to easily set the parameters.
For more information about the pylon Viewer, see Section 3.1 on page 25.
For more information about setting the state of user settable output signals, see Section 8.2.2 on
page 74.
For more information about working with the timer output signal, see Section 8.2.4 on page 76
By default, the Exposure Active signal is assigned to Output Line 1.