Basler SCOUT LIGHT Bedienungsanleitung Seite 80

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 228
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 79
Physical Interface AW00104701000
70 Basler scout light GigE
Fig. 23: Dependence of t
on90
and t
off10
on Voltage, for Different Load Currents; Measured for an Individual
Camera as an Example
Some general tendencies can be seen from the figure:
t
off10
increases as the voltage increases and as the load current decreases
t
on90
increases as the voltage and the load current increase
The effects due to different voltages and load currents are more pronounced on t
off1
than on
t
on90
.
50
30
40
20
10
0
Time [µs]
Voltage [V]
5 mA
50 mA
5 mA
50 mA
05
10
15
20
25 30
t
on90
t
off10
Seitenansicht 79