Image Acquisition Control AW00104701000
146 Basler scout light GigE
Formula 2:
Calculates the maximum frame rate based on the exposure time for the acquired frames:
Where the constant C
3
depends on the camera model as shown in the table below:
For more information about setting the exposure time, see Section 9.7 on page 121.
Formula 3:
Calculates the maximum frame rate based on the frame transmission time:
Camera Model C
1
C
2
Camera Model C
1
C
2
slA640-74gm/gc 22.66 µs 1433.66 µs slA1390-17gm/gc 46.53 µs 10244.54 µs
slA780-54gm/gc 26.94 µs 2308.54 µs slA1400-17gm/gc 46.53 µs 9357.50 µs
Camera Model C
3
Camera Model C
3
slA640-74gm/gc 84 µs slA1390-17gm/gc 177 µs
slA780-54gm/gc 100 µs slA1400-17gm/gc 175 µs
Max. Frames/s
1
Exposure time in µs C
3
+
--------------------------------------------------------------------=
Max. Frames/s
Device Current Throughput Parameter Value
Payload Size Parameter Value
------------------------------------------------------------------------------------------------------------------------=