Basic Operation and Features
Basler A500
k 3-19
PRELIMINARY
3.3.3 ExSync, Programmable Mode
When using the ExSync programmable mode to control exposure, several guidelines must be
followed:
ExSync must remain high for a minimum of 1 µs.
ExSync must remain low for a minimum of 1 µs.
Timer 1 must be set to a minimum of 10 µs.
Using full resolution, the minimum ExSync signal period is 2 ms for the A504
k/kc, 2.485 ms
for the A503
k and 13.52 ms for the A501k/kc.
If the AOI feature is used, the minimum ExSync signal period is equal to
1/Maximum Frame Rate where the maximum frame rate is determined by the suitable for-
mula in section 3.11.1.
Assuming that these general guidelines are followed, the reaction of the camera to a falling
ExSync signal will be one of four cases, which are described in sections 3.3.3.1, 3.3.3.2, 3.3.3.3
and 3.3.3.4.
L
The FlashOut signal can be set into a mode where it is high while the effective ex-
posure occurs, i.e. while the Integrate Enabled signal is high.