Smart Features
BASLER A620
f 6-21
DRAFT
Control and Status Register for the Test Image Feature
Register Name: Test Images
Address: See “Determining the Address of Smart Features CSRs” on page 6-4.
CSR GUID: 2A411342 - C0CA - 4368 - B46E - EE5DEEBF0548
Field Bit Description
Presence Inq
(Read only)
0 Presence of this feature
0: Not Available 1: Available
----- 1 ... 7 Reserved
Image Inq 1
(Read only)
8 Presence of test image 1
0: Not Available 1: Available
Image Inq 2
(Read only)
9 Presence of test image 2
0: Not Available 1: Available
Image Inq 3
(Read only)
10 Presence of test image 3
0: Not Available 1: Available
Image Inq 4
(Read only)
11 Presence of test image 4
0: Not Available 1: Available
Image Inq 5
(Read only)
12 Presence of test image 5
0: Not Available 1: Available
Image Inq 6
(Read only)
13 Presence of test image 6
0: Not Available 1: Available
Image Inq 7
(Read only)
14 Presence of test image 7
0: Not Available 1: Available
----- 15 Reserved
Image On
(Read / write)
16 ... 18 0: No test image active
1: Test image 1 active
2: Test image 2 active
3: Test image 3 active
----- 19 ... 31 Reserved