Features
110 Basler aviator Camera Link
Camera.BlackLevelRaw.SetValue( 0 );
// Set Black Level Raw Tap 3
Camera.BlackLevelSelector.SetValue ( BlackLevelSelector_Tap3 );
Camera.BlackLevelRaw.SetValue( 0 );
// Set Black Level Raw Tap 4
Camera.BlackLevelSelector.SetValue ( BlackLevelSelector_Tap4 );
Camera.BlackLevelRaw.SetValue( 0 );
You can also use the Basler pylon Viewer application to easily set the parameters.
For more information about the pylon API and the pylon Viewer, see Section 4 on page 45.
Setting the Black Level Using Direct Register Access
Setting the black level via direct register access is a several step process:
Set the value of the Black Level All register.
Set the value of the Black Level Tap 1 register.
Set the value of the Black Level Tap 2 register.
Set the value of the Black Level Tap 3 register.
Set the value of the Black Level Tap 4 register.
For more information about changing settings via direct register access, see Section 4 on page 45.
7.4.2 Black Level with One Tap Sensor Digitization
As mentioned in the "Functional Description" section of this manual, when the camera is set for one
tap sensor digitization, a single tap (electronic circuit) is used to read out the sensor. As a result of
this design, there is one black level parameter available when the camera is set for one tap
digitization: Black Level All.
The minimums, maximums, and adjustment methods for this parameter are similar to those
described in the previous section.